Monday, April 9, 2018

Supply heat, heating, cooling, air conditioning can't do things, air source heat pump can be done



In life, if you want to take a shower, we need to water heater; If you want to cooling, we need air conditioning; If you want to keep warm, we need electric heater. But have you ever thought, with the development of science and technology, to realize heating, refrigeration and heating, now actually need only one device can, it is the air source heat pump.
All around us, in fact, air source heat pump can be seen everywhere, but because most people lack the understanding of this product, is often seen, also did not realize that it is the air source heat ump. As a professional heat pump suppliers ,we can tell you that air source heat pump could be divided into many products, such as changes in temperature double heat for heat pump, directly heat pump, and can provide heating + hot water + cooling heat pump, we usually call it the full effect heat pump or trigeneration heat pump.

Trigeneration air source heat pump can rely on the inside of the heat pump refrigerant, the heat from the outside world, and then through the compressor power consumption of air source heat pump work, finally will have a hot water heat flux into the cold water. This way of heating ingenious use of the free calories in the air. A high heating efficiency. We know the electric water heater, heating efficiency is only about 95%. The air source heat pump heating efficiency can reach 400%. Air source heat pump hot water produced will save electricity more than electric water heater, ideally can 75% energy saving than the electric water heater. 
Winter heating electric heater at ordinary times, we can only provide a small area of the heating, the coverage of small, local temperature is too high, comfort in general. And the electric heater is coverts electrical energy into heat energy, power consumption is big. Air source heat pump heating is very simple, installed heating the end of the line. Common have a fan coil units, at the end of floor heating pipe and air source heating floor machine. 
Air source heat pump to provide hot water, hot water along the pipe to the end. If it is hang a wall to install fan coil units, from the sky blow out hot air for heating.If floor heating pipes, it is depend on the hot water flow in the pipe produced by thermal rediation for heating. If is the air source heating floor machine, hot water can be transformed to hot, blow out from the ground to keep warm. This end, several kinds of heating need hot water temperature is not high, are below 50. Air source heat ump can consume small amounts of electricity to produce more than 55 hot water, both match each other, high energy efficiency. 
Air source heat pump can refrigeration, but also for the cause of the refrigerant. In summer, heat pump can be like air conditioning, refrigerant is used to carry heat, transferring heat transfer from the interior. But with the air conditioning is different is that the air source heat pump in cooling, can also through the way of heat recovery for making hot water. So our summer cooling at the same time, also have the hot water can be used to take a bath.


Thursday, March 22, 2018

Air source heat pump water heater compare to electric water heater to save money

Guangteng top heat pump manufacturers
Air source heat pump water heater recently more fire, more and more people began to pay attention to this trendy water heater. Which is the most discussed is the energy problem. Some people think that air source heat pump water heater save power, but not save money. But there sare some people who say that the air source heat pump water heater as a whole is to save money. The two sides of the word, who is right?
To discuss whether the water heater energy saving, mainly to see its heating design. Air source heat pump water heater does not need to burn gas as gas water heater, it is somewhat similar to "electric water heater and solar water heater complex." Air source heat pump water heater is the use of refrigerant to absorb the heat in the outside air, and then to drive the compressor to work, after a series of heat transfer process, resulting in hot water. Although the air source heat pump water heater itself is power, but it is only for power consumption for the compressor, rather than the energy into heat. Thermal energy is mainly from the air free access to, so the air source heat pump water heater heating efficiency than electric water heater.


Electric water heater heating efficiency is about 95%, while the air source heat pump water heater heating efficiency according to the temperature changes in the 250% to 400% fluctuations. The general temperature reached 20 , air source heat pump water heater heating efficiency can reach 400%, if it is cold winter, air source heat pump water heater heating efficiency will be slightly decreased.

In theory, the air source heat pump water heater heating efficiency is 4 times the electric water heater, which is 75% energy saving than electric water heaters, electricity is also about a quarter of electric water heaters. So that the air source heat pump water heater energy saving, this view is right. But the province does not save money, which have to convert electricity into actual money to compare. According to the data show that if the daily supply of 200L hot water, hot water heated from 15 to 55 , air source heat pump water heater is less than 500 yuan a year, while the electric water heater needs more than 2,000 yuan. Daily electricity costs, air source heat pump water heater to a clear advantage to win.

In addition to electricity, the cost of the purchase of water heaters have to come in. A high-end electric water heater, priced at 2000 to 3,000 yuan. A high-end air source heat pump water heater, priced at 6000 ~ 7,000 yuan. On the initial investment, the electric water heater than the air source heat pump water heater cheap about 4,000 yuan, a huge advantage. But the water heater is generally used for many years, so we have to consider from the overall income.


An electric water heater, the service life only 6 to 8 years. Air source heat pump water heater, if usually properly maintained, the service life can generally reach more than 10 years. According to the theoretical value, the two-year electricity tariff gap can reach 1,500 yuan. However, due to different regions of the environment, in order to rigorous, here by a minimum of 1,000 yuan. Air source heat pump water heater use 4 years, the overall expenditure and electric water heater quite. The next few years, due to higher heating efficiency, so more power than electric water heaters.

Thursday, March 15, 2018

Air source heat pump floor heating is introduced

To warm the floor is the radiator, through the floor of the radiation layer of the heat medium, the uniform heating of the entire ground, the use of the ground itself, the heat and heat up the low of radiation from bottom to top, to achieve the purpose of heating. Water to warm refers to the water heated to a certain temperature, transported to the floor under the water pipe cooling network, through the floor heating and heating purposes to achieve a heating method, domestic heat pumps floor heating is one of the warm water.
Air to warm, also known as heat pump to warm, refers to the use of low-grade air in the air after compression through the compressor into high-temperature heat, the water temperature heated to 35 ~ 50 ℃, and as a heat medium in the dedicated pipeline circulation, heating floor decoration layer, through the ground radiation and convection heat transfer to the ground.
The heat in the air to the indoor heating, heating than electricity to 200%, safe 100%, 24 hours a day heating. Today, this set of the advantages of the above air to warm in the market quickly fire up, by the enthusiastic pursuit of consumers. From the safety and energy saving considerations, the air source heat pump water heater is undoubtedly the household water and household heating the best choice. Speaking of air source heat pump water heater, some consumers may not know what it is. Air source heat pump water heater by absorbing the heat in the air to heat the water, to achieve the separation of water and electricity, no emissions, is the safest and most energy efficient hot water equipment.
Of course, the air source heat pump water heater to promote the application is not only from a safe, energy-saving point of view to consider, but also from the user experience the comfort of departure. Air source to warm water heater, hot water and warm water completely independent, clean and safe, to provide users with a healthy natural, high quality heating and
bathing to enjoy. Relative to other heating methods, the air source to warm the water heater is more in line with the characteristics of human heating needs, room temperature from the bottom up gradually reduced to solve the cold from the foot of the problem, there will be no indoor dry, throat discomfort and other issues. Air to warm as heating and bathing hot water supply of the most energy-efficient equipment, input costs, low operating costs, comfortable experience, will become the mainstream of the future trend of heating.

Friday, March 2, 2018

Air source heat pump new market - infant swimming pool hot water supply

Infant swimming pool more common in cities, people’s living standards gradually increased after an emerging product. Swimming pool has a professional swimming pool, you can provide just enough comfort for the newborn child’s hot water swimming experience. The opening of a family of infants and young children’s swimming pool, but also to the relevant industrial chain began to be active. Among them, the air source heat pump hot water market as an important device, also ushered in the new development opportunities.
Air-source heat pump by a lot of infants and young children’s swimming pool owner to fancy, there are several reasons, the first to say is safe. Normally, equipment for supplying hot water to buildings includes oil-fired boilers and coal-fired boilers. Both of these facilities have an open flame during the heating process, posing a potential safety hazard. For infants and young children’s swimming pool this place has a demanding safety requirements, it is not so suitable.
Air source heat pump driven by electric energy, through the refrigerant absorbs heat in the air to produce hot water. Heating process, do not consume any fuel, natural gas, the flame does not appear to burn, so completely eliminate fire hazards. Heat pump heat exchanger also uses water and electricity separation design, but also reduce the probability of leakage of equipment at the root causes, has become the safe patron saint of the babies.
Then analyze the cost of air-source heat pump heating costs. In Guangzhou, there are quite a few cases of using the air source heat pump to heat the baby swimming pool. The author has obtained a detailed data from the list below. A baby swimming pool installed a 5P air source hot water unit. The installation cost of the project is about 20,000 yuan or so, which is about 8,000 yuan higher than the nearby swimming pool that uses oil-fired boiler heating.
However, in the subsequent use, the energy-saving effect of air-source heat pump gradually highlights. The use of oil-fired boiler heating, daily consumption of about 30L of fuel consumption, oil prices at 6.7 yuan / liter basis, the daily operation cost of oil-fired boilers over 200 yuan. Air source heat pump, as it is taken from the air, the daily power consumption is only about 20 kWh, commercial electricity price of 1.5 yuan / kWh, count down, heat pump daily operating costs only tens of dollars, far below the oil-fired boiler .
With the increase of newborns, air source heat pumps will also come one after another in the next few years in the market a small outbreak.

Tuesday, January 23, 2018

How to clean air source heat pump water heater

Air to Water Heat Pump water heater cleaning will help keep the normal work of the air source heat pump water heater, prolong the service life of heater, below is the air energy heat pump water heater cleaning steps of decomposition, non-professional workers do not imitate.
Tools/raw materialGloves, masks, air source heat pump water heater descaling cleaning agent
Pliers, screwdriver
Methods/procedures
  1. Under normal circumstances, the service life of air source heat pump water heater is very long, general life can take up to 15 years, air source water heater repair need professional personnel, so to maintain good air source water heater, good clean air source water heater is the key of the extend the service life of air source water heater.
    Air source heat pump water heater cleaning step down:
    First of all, on the advice of the experts the basic air source water heater is in use after a year you need to complete clean again, the actual situation according to the local water.
  2.  Before using, manually shut off the power, close the inlet valve and open the water valve, open the relief valve discharge valve counterclockwise 90 degrees, the air source water heater tank in the inland waters or play on their own emissions to moderate.
  3. Wear gloves and protective cover, the storage tank to store the right amount of water, and keep the cycle, and turn off the water side valve, drain valve closed.
  4. The air source heat pump water heater cleaner YT – 52-1 in accordance with the proportion of 1:5-10 add detergent into the water tank, circulating evenly.
  5. Open air source heat pump cycle for 2-3 hours, check the descaling solution PH value (or Ca2 + concentration) when no longer PH change or Ca2 + concentration rises, then add the original add one over ten of the dose, PH or Ca2 + concentration under test, continue to cleaning for 30 minutes, to measure the PH increase or Ca2 + concentration, not “need to continue to scale, if not change the scale has been divided.
  6. After completion of descaling, adding suitable amount of acid neutralizer YT- 51-8, and waste liquid of PH adjustment to 7-8, open the drain valve drainage of cleaning liquid.
  7. Close the drain valve,open the switch of water supply, into the right amount water, circulating cleaning after half an hour, then emissions, repeat the above process 2-3 times, is clean.

Monday, January 8, 2018

Air source heat pump units of defrosting method



With development of the trend of environmental protection and energy saving, the use of air source heat pump is gradually increasing, because in case temperature, air source heat pump in use process to frost phenomenon, affecting the performance of air source heat pump, today the air source heat pump defrosting methods to share with you. 
1. Stop frost: air source heat pump heat exchanger surface frost layer forms, too thick frost layer can reduce heating efficiency of the unit and increase power consumption, unit in this case the runtime also particularly prone to failure. Stop frost is the most convenient forms of air source heat pump units frost simple a way.
2. Reverse cycle defrost: switch the four-way reversing valve, which changes the flow of refrigerant, so as to achieve the effect of evaporator and condenser role exchange, close the fan, through the refrigerant of heat and the effect of the frost. This method is the most common of all the way to frost, frost process faster, improve the efficiency of the air source heat pump units of frost.
3. The hot gas bypass defrosting: open the hot gas bypass valve, turn off the fan, compressor exhaust will arrive through the hot gas bypass valve of liquid receiver, finally into the air cooled heat exchanger of defrosting.This way of defrosting effect is obvious and can not only shorten the time of frost. 
Timely to frost, air source heat pump units can not only improve the heating efficiency of the unit, also can reduce the damage to the equipment, can effectively increases the service life of air source heat pump units. Select the correct defrosting method can not only reduce the frost time, improve the working performance of the unit.


Monday, February 6, 2017

Air Source Heat Pump Water Heater Knowledge Quiz(2)



6. Heat pump water heater is solar products?
From the broad sense, but the heat pump water heater units with conventional solar products have essentially difference, mainly reflected in the different working principle; Conventional solar products must rely on sunlight direct radiation or radiation in order to achieve heating effect, while the heat pump unit mainly to absorb heat in the environment to achieve the heating effect.
7. Compared with the boiler heat pump products are his strengths?
(1) High thermal efficiency: the product will average thermal efficiency is above 300%, and the boiler thermal efficiency is not more than 100%.
(2) Low operating cost, and the fuel, gas boiler, energy and electricity price that day an average of 70% a year and lower fuel prices, increasing the advantages of low operating cost.

(3) Environmental protection, no combustion emissions heat pump products, refrigerant chose green refrigerant R417A, the zero pollution, ozone layer is very good and environmentally friendly products.
( 4) Operation safety, without unattended: compared with fuel boiler, absolutely safe operation, automatic control, unattended without personnel, personnel costs can be saved.Modular installation, easy to add equipment: the product adopts multiple units in parallel mode of installation, when a user of water increases, may at any time to add equipment, bring great convenience to the user.

Wednesday, January 11, 2017

Air Source Water Heater Daily Maintenance of Seven Elements



Air source heat pump water heater with its advantages gradually came into our life, as people increasingly use slowly, some problems also appeared, everyone has a question that how to maintain it?

1.  Air source heat pump water heater is a high degree of automation equipment, when used on a regular basis unit state examination, if the unit for long-term effective maintenance and maintenance, operation reliability and service life of the unit will have unexpected increase.

2.  Closed to install water filter should be cleaned regularly, ensure the water quality in the system is clean, in order to avoid host damage caused by filter dirty wall unit.

3
. The user should be paid attention to while using and maintenance of heat pump for heating units: unit within all safety protection devices are set to complete before they go out, don't disassembling or adjust itself.




4. Check the power supply of the air source heat pump water heater units and electrical system wiring whether firm, whether there is abnormal action electrical components, if any should be timely maintenance and replacement.

5. Always check the water system of filling water, water tank safety valve, liquid level controller and exhaust devices work is normal, in order to avoid air into the system resulting in a decrease of water quantity, which affects heat and the reliability of the unit operation of the unit.

 6.  Check the water pump, water is whether the valve works normally, the water and the pipe joint leakage.

7. The unit should be kept clean and dry, well ventilated, clean the air side heat exchanger a year, to maintain good heat transfer effect.

Tuesday, January 10, 2017

Daily Use and Maintenance of Household Water Circulation Air Source Water Heater

Air source water heater( heat pump water heater ) is a high degree of automation equipment, machine status on a regular basis to check when using, if can the machine for long-term and effective maintenance , reliable operation of the machine and to increase the service life will be unexpected.
1, The rating of the product to produce hot water temperature of 60 ℃, in order to prolong its service life, please use within the scope of the factory Settings, make use of will be out of place in the free warranty.The best energy saving water temperature in 46 to 52 ℃.

2,
Closed to install water filter should be cleaned regularly, ensure the water quality in the system is clean, in order to avoid the damage caused by filter blocking machine.

3,
 Inside the machine all the safety device are set before they go out, do not adjust.

4, Check whether the power of the machines and electrical system wiring and firm, whether there is abnormal action electrical components, if any should be timely maintenance and replacement.

5,
It is strictly prohibited by plugging (drawing) plug to switch machine directly, please check the leakage plug leakage protection function.

6,
Check the safety valve of the system of filling water, water tank and exhaust system work is normal, so as not to affect the machine's heat and the reliability of the machine running.

7,
Check whether water pipe joint leakage.

8, The machine should be kept clean and dry, well ventilated.Regular cleaning air side heat exchanger (3-6 months), to maintain good heat transfer effect.Must cut off power supply before cleaning, clean surface stains, please take a few neutral detergent scrub gently with wet cloth and, don't use gasoline or other solvents.Finish with a dry cloth to wipe dry, keep dry and water heater.
9,
Check the various parts of the host work, to check whether there is oil pipe machine and tapping, ensure the machine refrigerant leakage.

 10,
Machines do not pile up sundry, lest jam into the outlet, around the machine should be kept clean and dry, well ventilated.


11, If the downtime is longer, should put off the machine line in the water, and cut off power supply, set of good cover.Run time again, before starting on the system to conduct a comprehensive inspection.

12,
If the water heater is started reproduce any abnormal noise, please power off immediately, must be checked after troubleshooting can start again.

Thursday, December 29, 2016

How to Calculate the COP Value of Air Source Heat Pump Water Heater



COP value are very important index in many industries, in the middle of the air source heat pump water heater, represented by the heating coefficient of performance.Air source heat pump water heater in circulation work, the heating coefficient of performance COPh refers to in a certain condition, the compressor system with the same heat of the ratio of the compressor shaft power under the condition of PE.In simple terms, the COP is actually a heat pump system and the implementation of the heating and the ratio of the input power, under the same conditions, the ratio shows that the efficiency of the heat pump system, the higher the more the greater the energy saving.



The user wants to know the source of the COP value, can under standard conditions were calculated by formula.Air source heat pump water heater under standard conditions: temperature 25 degrees, the water temperature of 15 degrees.Water temperature from 15 degrees heat to 55 degrees, measured power consumption for W;Water temperature from 15 degrees heat to 55 degrees, the time required for t;Tank measured net capacity to remember L;Water heat gain as: Q=C*L*△T, average water heater heating capacity is: Q = Q/T, water heater of the average power consumption is: P = W/T, measured the COP for standard conditions: COP = q/P=C*L*△T/W.



In addition to the above way, consumers can also be concluded that COP value in the simple way, such as air source heat pump for heating system heat is P1 (KW) of the rated power of the heat pump is P2 (KW) then the COP = P1 / P2.Air source heat pump water heater of COP value not only receive the objective external environment influence, also will be affected by their own factors, such as the coefficient of performance of the compressor, heat pump system: (the so-called system match is to point to: compressor, condenser, evaporator, throttle body and the matching performance of automatic control system.)Obtained from the COP value is more than just air can water heater can effect comparing, can be roughly understanding to the matching performance between the internal parts.